Induced Draft (ID) Fans
An induced draft (ID) fan is an integral part of a boiler's combustion system. The device is designed to pull flue gases from the combustion chamber to the stack and then circulate them throughout the rest of the boiler assembly. The amount of flue gas that the fan draws depends on the head of the fan and the pressure drop across all equipment within its path.
Induced draft (ID) fans are ideal for use in high-temperature, harsh conditions. However, they can be expensive to maintain. These units may require frequent vibration testing, bearing lubrication, and fan cleaning. If they fail prematurely, these fans can result in costly plant shutdowns
Induced draft fans are typically placed between the boiler and the dust collector to remove hot flue gases from the combustion chamber. The fans create negative pressure in the airstream, which is necessary to facilitate heat transfer. They are often used in conjunction with FD fans for enhanced system efficiency.

Types of ID fans
Induced draft fans (ID fans) are used in boilers and thermal oil heaters. Their primary purpose is to extract air from the system and create negative pressure. They are located at the outlet of the boiler system, and they provide tremendous value from an energy efficiency perspective. These fans do not use a lot of electricity and can greatly reduce electricity bills. They also work effectively to move hot flue gases, but they also face risks, including corrosion and erosion.
Boiler ID fans come in two basic types: centrifugal and axial flow. The former forces outside air into the heating system while the latter draws flue gases out of the boiler. These two types of fans help balance the air system inside the boiler and promote a more efficient combustion process.
FD and PA fans work in a similar way. FD fans are more powerful and have a greater static pressure. PA fans are used in coal-fired boilers, but have a smaller capacity. The latter is required for boilers with air quality equipment at the back.
Maintenance of ID fans
Regular maintenance of boiler ID fans is an important aspect of ensuring boiler performance. Boiler fans come in a variety of types. There are ID fans and FD fans. While the ID fan produces more air than the FD fan, both fans have the same flow capacity. FD fans are also more efficient than ID fans, with a 96% efficiency rating. When the fan is not performing up to par, it will automatically trip the boiler.
ID fans should be designed to withstand high temperatures generated by the combustion process. Besides the normal operating temperature, the design temperature should also be high enough to prevent major components from breaking down under unexpected high temperatures. In addition to this, major components should also be shut down in case of malfunction.
The Bottom Line
Boiler ID fans are a proven energy-efficient way to increase boiler efficiency. The savings achieved by these devices can be significant. These fans are used in coal and biomass-firing applications and many other industries for their benefits.